![Measurement Sensor Keyence LK-G5001P](https://static.famaga.ru/uploads/images/product/large/29051fdeffb42230640b8c8de7632a7e.jpg)
FAMAGA always strives to provide the best prices and timings of supplies for its customers. We sell only original equipment and spare parts, although we are not always the official distributor or manufacturer's dealer. All displayed trademarks and part numbers are the property of their respective owners.
On website of FAMAGA you can buy Measurement Sensor Keyence LK-G5001P, and many other spare parts from the
Keyence with delivery all over the United States, including: Dublin.For price list, delivery
timings and other product features of the Keyence, please, fill in the feedback form or send a description
of goods you need to our e-mail sales@famaga.us
![PayPal](/assets/public/images/paypal.jpg)
![SWIFT Wire Transfer](/assets/public/images/wire.jpg)
Description
Controller, PNP TypeModel | LK-G5001P | |
Type | Separate type Main controller | |
Sensor head compatibility | Compatible | |
No. of connectable sensor heads | 2 | |
Display | Minimum display unit | 0.001 µm |
Display range | ±999.999 µm to ±9999.99 mm (7 settings selectable) | |
Display cycle | Approx 10 times/sec. | |
Display interface | Display port | Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected |
LED indicator | LASER ON | |
Terminal block | Analogue output voltage | ±10 V output, Output impedance: 100 ?*1 |
Analogue current output | 4 to 20 mA, Maximum load resistance: 350 ?*1 | |
No. of analogue outputs | 2*1 | |
TIMING 1 input | Voltage input*2 | |
RESET 1 input | ||
Auto-zero 1 input | ||
Laser remote input | Non-voltage input*1 | |
Alarm output | PNP open-collector output*1 | |
General comparator output | ||
Expansion connector | TIMING input | Voltage input*1 |
RESET input | ||
Auto-zero input | ||
Program switching input | ||
Binary selection input | ||
Alarm output | PNP open-collector output*1 | |
Comparator output | ||
Binary output | ||
RS-232C interface | Baud rate: 9600 to 115200 bps Data length: 8 bits Stop bit length: 1 bit Parity: None/even/odd | |
USB interface | USB 2.0 Hi-Speed compliant*3 | |
Ethernet interface | 100Base-TX/10Base-T*4 | |
EtherNet/IPTMinterface | Cyclic communication (implicit messaging) Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*5 | |
PLC-Link | The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series EtherNet/IPTM, CC-Link, and DeviceNetTM cannot be used in conjunction with PLC-Link | |
Head expansion unit connector | Up to 10 head expansion units can be connected to one main controller | |
Expansion unit connector | Either of the CC-Link unit (LK-CC100) or DeviceNetTM unit (LK-DN100) can be connected | |
Power supply | Power supply voltage | 24 VDC ±10% |
Maximum current consumption | 0.6 A or less with 1 head/3.5 A or less with 12 heads | |
Environmental resistance | Ambient temperature | When one or less head expansion unit is connected: 0 to +50 °C. When two or more head expansion units are connected: 0 to +40 °C. |
Relative humidity | 35 to 85 % RH (No condensation) | |
Weight | Approx. 600 g | |
*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max. PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max. Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max. Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to 'Precautions on wiring' in the User's Manual. *2 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max. PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max. Non-voltage input rating: ON voltage: 1 V max., OFF current: 0.6 mA max. Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to 'Precautions on wiring' in the User's Manual. This input is applied to all of the synchronised OUT. *3 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down. *4 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units. *5 The EtherNet/IPTM interface cannot be used when a CC-Link unit or a DeviceNetTM unit is installed. EtherNet/IPTM is supported by the latest controllers. For details on which controllers support EtherNet/IPTM , contact your nearest KEYENCE office. |
We can compile your order
according to your purchasing list.
This service offers more comfort for our customers. Just upload the list of equipment you need.
Sending...
The message hasn't been sent
The message hasn't been sent
The request has been sent
The request has been sent
To the top of the page
New order
Just now
Manufacturer
Keyence