Headquater is in
the centre of Europe
Warranty is up
to 12 months
to 12 months
Best
prices
prices
Savings varies
from 15 to 55%
from 15 to 55%
Shipping
worldwide
worldwide
All shipments
are insured
are insured
Free
shipping
shipping
![Measurement Systems Keyence IM-7020](https://static.famaga.ru/uploads/images/product/large/3598a1dcc162e4ea887d7f6d7610cb6e.jpg)
FAMAGA always strives to provide the best prices and timings of supplies for its customers. We sell only original equipment and spare parts, although we are not always the official distributor or manufacturer's dealer. All displayed trademarks and part numbers are the property of their respective owners.
On website of FAMAGA you can buy Measurement Systems Keyence IM-7020, and many other spare parts from the
Keyence with delivery all over the United States, including: Dublin.For price list, delivery
timings and other product features of the Keyence, please, fill in the feedback form or send a description
of goods you need to our e-mail sales@famaga.us
![PayPal](/assets/public/images/paypal.jpg)
![SWIFT Wire Transfer](/assets/public/images/wire.jpg)
Description
Measurement HeadModel | IM-7020 | |
Type | Head Model incorporating backlighting/programmable ring-illumination unit/light probe unit | |
Image sensor | 1” 6.6 mega pixel monochrome CMOS | |
Display | 10. 4” LCD monitor (XGA: 1024 ? 768) | |
Receiver lens | Double telecentric lens | |
Image measurement | Field of view | Wide-field measurement mode: 200 mm ? 200 mm (4 ? R50) High-precision measurement mode: 125 ? 125 mm |
Minimum display unit | 0.1 µm | |
Repeatability | W/o stage movement | Wide-field measurement mode: ±1 µm High-precision measurement mode: ±0.5 µm |
With stage movement | Wide-field measurement mode: ±2 µm High-precision measurement mode: ±1.5 µm | |
Measurement accuracy (±2?) | W/o binding | Wide-field measurement mode: ±5 µm*1 High-precision measurement mode: ±2 µm*2 |
With binding | Wide-field measurement mode: ± (7 + 0.02 L) µm*3 High-precision measurement mode: ± (4 + 0.02L) µm*4 | |
Light probe Measurement | Measurable area (XY) | 90 ? 90 mm |
Maximum measurement depth | 30 mm | |
Light probe diameter | o3 mm | |
Measuring force | 0.015 N | |
Repeatability | ±2 µm*5 | |
Measurement accuracy | ± (8 + 0.02 L) µm*6 | |
External remote input | Non-voltage input (with and without contact) | |
External output | OK/NG/FAIL/MEAS. | PhotoMos output Rated load 24 VDC 0.5 A ON resistance 50 m? or lower |
Interface | LAN | RJ-45 (10BASE-T/100BASE-TX/1000BASE-T) |
USB 2.0 series A | 6 ports (front: 2, rear: 4) | |
Record | Hard disk drive | 500 GB |
Illumination system | Transparent | Telecentric transparent illumination |
Ring | Four division, multi-angle illumination (electric) Slit ring (directivity) illumination (electric) | |
XY stage | Moving range | 100 ? 100 mm (electric) |
Withstand load | 5 kg | |
Z stage | Moving range | 75 mm (electric) |
Power supply | Power voltage | 100 to 240 VAC 50/60 Hz |
Power consumption | 430 VA or lower | |
Environmental resistance | Pollution degree | 2 |
Overvoltage category | II | |
Ambient temperature | +10 to +35 °C | |
Relative humidity | 20 to 80 % RH (No condensation) | |
Weight | Approx. 31 kg | |
*1 In the range of o80 mm, within the operating ambient temperature range of +23°C ±1°C at the focused focal point position *2 In the range of o20 mm within the operating ambient temperature range of +23°C ±1°C at the focused focal point position *3 In the range of 180 ? 180 mm (4 ? R40), within the operating ambient temperature range of +23°C ±1°C at the focused focal point position, and with a load weighing 2 kg or less on the stage (L = amount of stage movement in mm units) *4 In the range of 120 ? 120 mm, within the operating ambient temperature range of +23°C ±1°C at the focused focal point position, and with a load weighing 2 kg or less on the stage (L = amount of stage movement in mm units) *5 When the detection system is standard. If the detection system is at a deep position, then ±3 µm *6 When the detection system is standard, and the ambient temperature is 23°C ±1°C, with a stage load weighing 2 kg or less. If the detection system is at a deep position, then ± (10 + 0.02 L) µm with L as the measurement length in mm. |
We can compile your order
according to your purchasing list.
This service offers more comfort for our customers. Just upload the list of equipment you need.
Sending...
The message hasn't been sent
The message hasn't been sent
The request has been sent
The request has been sent
To the top of the page
New order
Just now
Manufacturer
Keyence