LABOM

FAMAGA always strives to provide the best prices and timings of supplies for its customers. We sell only original equipment and spare parts, although we are not always the official distributor or manufacturer's dealer. All displayed trademarks and part numbers are the property of their respective owners.
Our catalog contains the entire product line of the LABOM manufacturer at good prices with door-to-door delivery to any region of United States, including your area: Dublin. Our managers will help you to select and buy suitable LABOM product or spare part, just right after sending an application form. To find out the prices and delivery time, please fill in the feedback form or send your inquiry to sales@famaga.us
Get a price
PayPal SWIFT Wire Transfer
Our catalog contains the entire product line of the LABOM manufacturer at good prices with door-to-door delivery to any region of United States, including your area: Dublin. Our managers will help you to select and buy suitable LABOM product or spare part, just right after sending an application form. To find out the prices and delivery time, please fill in the feedback form or send your inquiry to sales@famaga.us

We deliver equipment of LABOM
throughout the world

Just now
This week
Earlier than a week
Last order date
Order list
14.06.2021
CV3110-A1059-F80-H1100-M1-Y4-N51-T6-T31-K1085-W4020-W2002 DL9016-HY-E1-G1-A400-L22 CV3110 PRESSURE TRANSMITTER PASCAL CV, for diaphragm seal operation, hygienic acc. to data sheet D4-017/22 A1 pressure sensor: piezoresistive for gauge pressure 059 nominal range: 0...16 bar, overload limit 60 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F80 measuring range: setting see below lower range value: - 1,000 upper range value: + 15,000 unit: bar H11 output signal: 4...20 mA, rising characteristic (standard) 0 setting damping: 0.0 sec. (standard) 0 setting alarm state: < 3.6 mA (standard) M1 display module: without Y4 screw cap with window mat. Macrolon N5 switching module: with 2 floating channels, pluggable, electrically isolated at all sides, switching capacity 30 V DC / 0.5 A 1 switching module setting: at the factory, see below 1. switch contact: switch point: 8 bar breaker hysteresis:0,1% (falling) 2. switch contact: switch point: 10 bar breaker hysteresis:0,1% (falling) T6 case: hygienic design with screw cap material: stainless steel degree of protection: IP 66 incl, vent filter, stainless steel T31 electrical connection: circular connector M 12x1 (8 pin) K1085 design standard W4020 ADDITIONAL DESIGN: marking (adhesive label), see below W2002 CALIBRATION PROTOCOL: with 5 measuring points DL9 DIAPHRAGM SEAL for food/pharmaceutical/biotechnology 016 design: APV flange design HY hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm E1 basic body material: stainless steel (316L) G1 diaphragm material: stainless steel (316L) A400 connection of meas. instrument directly welded L22 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered operating temperature range -10...+140 °C spare parts for fab.-no.: 1819962/10/003
Get a price

More than 70,000 completed orders

GA251 RESISTANCE THERMOMETER Pt 100 with thermowell
see data sheet T4-025-2
0 explosion protection: without
A10 process connection: G 1/2 B
1 material process connection: stainless steel mat.-no. 1.4571 (316Ti)
B43 thermowell length total L: 395 mm
C12 thermowell diameter: F1 = 9 mm
1 material thermowell: stainless steel mat.-no. 1.4571 (316Ti)
300 insertion length U1: 300 mm
length of measuring insert l5: 405 mm
D2 measuring insert: ø 6 mm, rigid
M2 tolerance: class A per DIN EN 60751
2 application range: -50...+400°C
N2 sensor type: 1 x Pt100, 3-wire technology
T11 connection head: model B, cap with 2 slotted screws, IP 54
material: aluminium
electrical connection: M20x1.5 cable gland for cable ø 9-14 mm, material
nickel-plated brass
W2674 EAC-TR certification exemption statement LABOM
26.07.2021
Order
GA2510-A101-B43-C121300-D2-M22-N2-T11-W2674 GA251 RESISTANCE THERMOMETER Pt 100 with thermowell see data sheet T4-025-2 0 explosion protection: without A10 process connection: G 1/2 B 1 material process connection: stainless steel mat.-no. 1.4571 (316Ti) B43 thermowell length total L: 395 mm C12 thermowell diameter: F1 = 9 mm 1 material thermowell: stainless steel mat.-no. 1.4571 (316Ti) 300 insertion length U1: 300 mm length of measuring insert l5: 405 mm D2 measuring insert: ø 6 mm, rigid M2 tolerance: class A per DIN EN 60751 2 application range: -50...+400°C N2 sensor type: 1 x Pt100, 3-wire technology T11 connection head: model B, cap with 2 slotted screws, IP 54 material: aluminium electrical connection: M20x1.5 cable gland for cable ø 9-14 mm, material nickel-plated brass W2674 EAC-TR certification exemption statement
PRESSURE TRANSMITTER COMPACT for diaphragm seal operation LABOM
25.05.2021
Order
CC6020-A1061-H1-T130 DL5110-S1203-HY-A4007-L22-W1020 PRESSURE TRANSMITTER COMPACT for diaphragm seal operation
CB6  COMPACT PRESSURE TRANSMITTER with threaded connection
01 design: internal diaphragm
0 explosion protection: without
A1 pressure sensor: piezoresistive for gauge pressure
999 measuring range see below
-1...17 bar, overload limit 60 bar
H1 output signal: 4...20 mA, 2-wire technology
K1010 process connection: G1/2 B nach DIN 837-1
material wetted parts
T110 - sensor diaphragm, stainless steel mat. no. 1.4404/1.4435 (316L)
- socket, stainless steel mat. no. 1.4404/1.4435 (316L)
electrical connection: right angle plug acc. to DIN EN 175301-803-A (DIN
43650, model A), IP 65 LABOM
08.12.2020
Order
CB6010-A1999-H1-K1010-T110 CB6 COMPACT PRESSURE TRANSMITTER with threaded connection 01 design: internal diaphragm 0 explosion protection: without A1 pressure sensor: piezoresistive for gauge pressure 999 measuring range see below -1...17 bar, overload limit 60 bar H1 output signal: 4...20 mA, 2-wire technology K1010 process connection: G1/2 B nach DIN 837-1 material wetted parts T110 - sensor diaphragm, stainless steel mat. no. 1.4404/1.4435 (316L) - socket, stainless steel mat. no. 1.4404/1.4435 (316L) electrical connection: right angle plug acc. to DIN EN 175301-803-A (DIN 43650, model A), IP 65
 

We can compile your order
according to your purchasing list.

This service offers more comfort for our customers. Just upload the list of equipment you need.
  • Enter your name
  • Enter your contact phone number.
  • Enter your email address
To the top of the page
New order Just now
Manufacturer
LABOM