We deliver equipment of LABOM
throughout the world

Just now
This week
Earlier than a week
Last order date
Order list
14.06.2021
CV3110-A1059-F80-H1100-M1-Y4-N51-T6-T31-K1085-W4020-W2002 DL9016-HY-E1-G1-A400-L22 CV3110 PRESSURE TRANSMITTER PASCAL CV, for diaphragm seal operation, hygienic acc. to data sheet D4-017/22 A1 pressure sensor: piezoresistive for gauge pressure 059 nominal range: 0...16 bar, overload limit 60 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F80 measuring range: setting see below lower range value: - 1,000 upper range value: + 15,000 unit: bar H11 output signal: 4...20 mA, rising characteristic (standard) 0 setting damping: 0.0 sec. (standard) 0 setting alarm state: < 3.6 mA (standard) M1 display module: without Y4 screw cap with window mat. Macrolon N5 switching module: with 2 floating channels, pluggable, electrically isolated at all sides, switching capacity 30 V DC / 0.5 A 1 switching module setting: at the factory, see below 1. switch contact: switch point: 8 bar breaker hysteresis:0,1% (falling) 2. switch contact: switch point: 10 bar breaker hysteresis:0,1% (falling) T6 case: hygienic design with screw cap material: stainless steel degree of protection: IP 66 incl, vent filter, stainless steel T31 electrical connection: circular connector M 12x1 (8 pin) K1085 design standard W4020 ADDITIONAL DESIGN: marking (adhesive label), see below W2002 CALIBRATION PROTOCOL: with 5 measuring points DL9 DIAPHRAGM SEAL for food/pharmaceutical/biotechnology 016 design: APV flange design HY hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm E1 basic body material: stainless steel (316L) G1 diaphragm material: stainless steel (316L) A400 connection of meas. instrument directly welded L22 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered operating temperature range -10...+140 °C spare parts for fab.-no.: 1819962/10/003
Get a price
4.02.2021
CV3110-B1059-F10-H1100-M1-N50-T31-K1085 DD4100-HY-A4007-L22 CV3110 PRESSURE TRANSMITTER PASCAL CV, for diaphragm seal operation, hygienic acc. to data sheet D4-017/22 B1 pressure sensor: piezoresistive for absolute pressure 059 nominal range: 0...16 bar abs., overload limit 60 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F10 measuring range: 0...16.00 bar abs. H11 output signal: 4...20 mA, rising characteristic (standard) 0 setting damping: 0.0 sec. (standard) 0 setting alarm state: < 3.6 mA (standard) M1 display module: without screw cap closed, without window N5 switching module: with 2 floating channels, pluggable, electrically isolated at all sides, switching capacity 30 V DC / 0.5 A 0 switching module setting: standard, see below 1. switch contact: switch point: 50 % breaker, hysteresis: 0.1 %, falling, standard 2. switch contact: switch point: 50 % breaker, hysteresis: 0.1 %, falling, standard case: hygienic housing design with screw cap material: stainless steel degree of protection: IP 66 T31 electrical connection: circular connector M 12x1 (8 pin) K1085 design standard DD4 DIAPHRAGM SEAL for food/pharmaceutical/biotechnology DRD-connection acc. to data sheet D5-024-4 100 nominal width/pressure: DN 50 / PN 40 HY hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 µm - diaphragm Ra <= 0.38 µm - weld seam Ra <= 0.76 µm A400 connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) L22 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered operating temperature range -10...+140 °C
Get a price
15.12.2020
Get a price
26.11.2020
Get a price
28.08.2020
Get a price
12.08.2020
Get a price
5.05.2020
Get a price
3.03.2020
Get a price
3.03.2020
Get a price
30.01.2020
Get a price
30.01.2020
Get a price
30.01.2020
Get a price
18.11.2019
Get a price
28.10.2019
Get a price
28.10.2019
Get a price
28.10.2019
Get a price
2.08.2019
Get a price
30.07.2019
Get a price
19.07.2018
Get a price
27.03.2018
MZ1100-B901-W2002 CC6010-A1089-H1-T410 BH4210-A89 DL3230-HY06-A4007-L23-T14-W1020 MZ1100 COMBIBAR PRESSURE MEASURING SYSTEM B901drawing no.: see below as per drawing PD-WC-00025 W2002 CALIBRATION PROTOCOL: with 5 measuring points CC6 PRESSURE TRANSMITTER COMPACT with diaphragm seal 01 design: standard 0 explosion protection: without A1 pressure sensor piezoresistive for gauge pressure 089 measuring range -1...3 bar, overload limit 20 bar measuring accuracy: linearity error incl. hysteresis < + 0.2 % f.s. accuracy of adjustment < +/- 0.2 % f.s. H1 output signal: 4...20 mA, 2-wire technology T410 electrical connection: field housing of stainless steel, with cable gland, IP 65 BH4 BOURDON TUBE PRESSURE GAUGE with diaphragm seal connection, chemical design acc. to data sheet D2-029 2 case: DN 100 10 case design: IP 65, process connection at back A accuracy: class 1.0 per EN 837-1 89 nominal range: -1...3 bar pointer: with micro adjustment DL DIAPHRAGM SEAL for food / pharmaceutical / biotechnology 3 design with clamp connection see data sheet D5-026 230 process connection: per DIN 32676 model C (Tri-Clamp) for pipes per ASME BPE, DN 1 1/2" / PN 25 HY06 hygienic design per EHEDG Doc.8 and ASME BPE SF1: surface rouhgness (wetted parts) - turned parts Ra <= 0.51 µm - diaphragm Ra <= 0.38 µm - weld seam Ra <= 0.76 µm A400 connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) L23 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered T14 design temperature, media: -10..+150 °C W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts Spare Part for serial no. 1511104/05/001-002
Get a price
27.03.2018
GA2730-A10-C3998-M2-N2-T150-Z52-W2002 HP1200-HY06-A25-B1412-E2100-G11-W1020 PA2430-F12-H1 GA2730 RESISTANCE THERMOMETER MiniTherm for installation in separate thermowell acc. to data sheet T4-017 A10 instrument connection: union nut M12x1 C3 temperature detecting element: ø 3 mm 998 insertion length l1: to suit thermowell M2 measuring insert: class A as per DIN 60751 N2 sensor type: 1 x Pt100, 3-wire technology T150 electrical connection: circular connector M12 x 1 (4 pins) Z52 incl. transmitter into st. steel plug housing with locking plug M12 (type PA2430) W2002 CALIBRATION PROTOCOL: with 5 measuring points HP1200 THERMOWELL, Type Series HP1200 acc. to data sheet T5-051 HY06 hygienic design: surface roughness (wetted parts) - turned parts Ra <= 0.6 µm - weld seam Ra <= 1.6 µm A25 instrument connection: M12x1 B1412 process connection: clamp connenction ø 50.5 mm DIN 32676 model A (metric) DN 25 / 32 / 40 DIN 32676 model B (OD, ISO) DN 21.3 / 26.9 / 33.7 / 42.4 DIN 32676 model C (inch, Tri-Clamp) 1" / 1 1/2" ISO 2852 DN 25 / 33.7 / 38 E2 thermowell diameter: ø 6 mm, reduced design to ø 4 mm 100 insertion length U1: 100 mm G11 material: stainless steel mat.-no. 1.4404 (316L) W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts PA243 TRANSMITTER for temperature (Pt 100), programmable see data-sheet T4-082-1 with circular connector M12x1 (4-pins) 0 design: standard F12 configuration: see below measuring range: 0...+150 °C error current if there is a sensor break 22.8 mA sensor offset: 0 °C, standard damping: 0 s, standard H1 output signal: 4...20 mA, standard Spare Part for serial no. 1511104/04/001
Get a price
2.03.2017
Get a price
13.09.2016
Get a price