- R&S®FS-K30 Application Firmware for Noise Figure and Gain Measurements for R&S®FSP, R&S®FSU and R&S®FSQ (preamplifier recommended, e.g. R&S®FSU-B23, R&S®FSU-B24, R&S®FSU-B25)
R&S®FS-K30 Application Firmware for Noise Figure and Gain Measurements for R&S®FSP, R&S®FSU and R&S®FSQ (preamplifier recommended, e.g. R&S®FSU-B23, R&S®FSU-B24, R&S®FSU-B25)
Category - Analyzers
Get a price
On website of FAMAGA you can buy R&S®FS-K30 Application Firmware for Noise Figure and Gain Measurements for R&S®FSP, R&S®FSU and R&S®FSQ (preamplifier recommended, e.g. R&S®FSU-B23, R&S®FSU-B24, R&S®FSU-B25), and many other spare parts from the
Rohde & Schwarz with delivery all over the United States, including: Dublin.For price list, delivery
timings and other product features of the Rohde & Schwarz, please, fill in the feedback form or send a description
of goods you need to our e-mail sales@famaga.us
Description
Outperforming any conventional noise measurement systemKey Facts Application Firmware R&S®FS-K30 provides the high-grade analyzers with features otherwise only provided by special noise measurement systems. At a specified frequency or in a selectable frequency range the following parameters can be measured:
- Noise figure in dB
- Noise temperature in K
- Gain in dB
Features & Benefits
- The combination of Application Firmware R&S®FS-K30 and Analyzers R&S®FSP/FSU or R&S®FSQ offers the following advantages over conventional noise measurement systems:
- Frequency range up to 67 GHz (depending on analyzer model) for noise measurements in the micro wave range without requiring an additional downconverter
- Resolution bandwidths variable in steps of 1/2/3/5 (R&S®FSP: only 1/3) for optimum matching to narrowband DUTs
- Harmonics
- Intermodulation
- Spurious responses
- Noise measurements
- Level range 0 dB to 25 dB
- Resolution 0.01 dB
- Measurement accuracy ±0.2 dB (measurement with preamplifier (gain 20 dB, noise figure 5 dB) and 1 MHz bandwidth, valid for DUTs with noise figure 1 dB to 10 dB and gain >10 dB)
- Gain measurements
- Level range 0 dB to 60 dB
- Resolution 0.01 dB
- Measurement accuracy ± 0.2 dB (preamplification 20 dB, noise figure 5 dB, bandwidth 1 MHz)
We can compile your order
according to your purchasing list.
This service offers more comfort for our customers. Just upload the list of equipment you need.
Sending...
The message hasn't been sent
The request has been sent
To the top of the page
Manufacturer
ROHDE SCHWARZ