On website of FAMAGA you can buy R&S®TS-PIO4 Digital Functional Test Module, and many other spare parts from the
Rohde & Schwarz with delivery all over the United States, including: Dublin.For price list, delivery
timings and other product features of the Rohde & Schwarz, please, fill in the feedback form or send a description
of goods you need to our e-mail sales@famaga.us
Description
32?channel programmable digital I/O moduleKey Facts
- 32 digital input and 32 digital output channels
- 40 MHz sample rate, depending on levels and number of channels
- FPGA-based flexibility and realtime task execution independent of operating system used
- 12.5 ns resolution
- 8 groups of 4 channels each: –6 V to +10 V
- Tristate control for every output channel in dynamic mode
- Programmable DIO level (high and low) per group with 14 bit resolution
- Two programmable input threshold levels per group for hysteresis or level monitoring
- High output current with 150 mA per channel
- Synchronization/triggering (bidirectional) via PXI trigger bus or XTI (TTL)
- External clock input via EXT_CLK input pin (TTL)
- Selftest software
- Soft front panels for immediate use
- LabWindows/CVI device driver support
- Test software library R&S®GTSL in DLL format
Brief Description The R&S®TS-PIO4 digital functional test module contains flexibly programmable 32-bit digital inputs and 32-bit digital outputs that are able to acquire and stimulate static or dynamic digital patterns. The R&S®TS-PIO4 digital functional test module is a compact PCI/PXI module that takes up only one slot on the R&S®CompactTSVP test system versatile platform. The characteristics of the digital lines can be configured with 14 bit resolution levels per port. In addition, the levels of the output ports can be programmed to meet application requirements. The input ports have a programmable threshold and hysteresis to match the specifications of common digital logic families.
Specifications
Use on R&S®CompactTSVP platform | ||
R&S®CompactTSVP | 1 slot required | |
Interfaces | ||
Control bus | CompactPCI/PXI | |
DUT connector (front) | DIN 41612, 96 pins | |
Rear I/O connector | CompactPCI connector, 110 pins | |
Module features | ||
Data input channels | ||
Channels | single-ended channels | 32, on 8 ports of 4 bit |
Input modes 1) | hysteresis, comparator | |
Input levels 2) | clamping if outside range | |
range 0 | –7.5 V to +10.0 V | |
range 1 | –5.0 V to +12.0 V | |
range 2 | –3.3 V to +12.0 V | |
range 3 | 0.0 V to +12.0 V | |
Input thresholds 2) | two programmable thresholds, 14 bit resolution | |
range 0 | –6.0 V to +5.1 V | |
range 1 | –3.5 V to +7.1 V | |
range 2 | –1.8 V to +7.1 V | |
range 3 | +1.5 V to +7.1 V | |
Input resistance | 1 M? | |
Signal acquisition timing | ||
Sample rate | 0.01 Hz to 40 MHz with 12.5 ns resolution, depending on levels and number of channels | |
Trigger delay | 50 ns to 50 s with 12.5 ns resolution | |
Data buffer depth/width | programmable | 2 Msample at 32 bit (IN 1 to IN 32) |
Protection | ||
Overvoltage protection | ±24 V | |
Data output channels | ||
Channels | single-ended channels | 32, on 8 ports of 4 bit, the number of channels that can be simultaneously used depends on the level range, frequency and load 2) |
Output modes | analog, tristate | |
Analog output mode 2) | output voltage | |
range 0 | VL = –6.0 V to –1.5 V | |
VH = –6.0 V to +8.0 V | ||
range 1 | VL = –3.5 V to +1.0 V | |
VH = –3.5 V to +10.0 V | ||
range 2 | VL = –1.8 V to +2.7 V | |
VH = –1.8 V to +10.0 V | ||
range 3 | VL = +1.5 V to +6.0 V | |
VH = +1.5 V to +10.0 V | ||
output current | max. 150 mA per channel, 10 mA to 350 mA per port 1) | |
output resolution | 14 bit | |
Tristate control output mode | output voltage | none |
Output resistance | typ. 30 ? | |
Realtime stimulation 1) | ||
Sample rate | 0.01 Hz to 40 MHz at 12.5 ns resolution, depending on levels and number of channels | |
Trigger delay | 50 ns to 50 s at 12.5 ns resolution | |
Data buffer depth/width | programmable | 2 Msample at 32 bits (OUT 1 to OUT 32) |
Implementation of bidirectional data buses | tristate control | programmable, per sample, portwise connection of data input with data output channels via onboard analog switches |
Protection | short-circuit | reverse voltage up to ±24 V at 150 mA |
Relay channel | ||
Ground-relay channel | ground relay to disconnect chassis ground for in?circuit tests (ICT) | SPST, to ground |
Maximum switching voltage | DC/AC | 30 V/125 V (RMS) |
Maximum switching current | DC/AC | 2 A/0.5 A (RMS) |
Maximum switching power | DC/AC | 60 W/62.5 VA |
Pattern comparator | ||
Comparison | 32-bit data input channel pattern with 32-bit reference pattern, 32-bit comparison enable mask | |
Applications | ||
Frequency measurement 3) | maximum input frequency | 10 MHz at 50 % duty cycle |
minimum pulse width | 50 ns | |
frequency resolution | 25 ns | |
measurement time | 200 ns to 50 s gate time or up to 232 – 1 comparator matches | |
trigger | software trigger | |
Event counting 3) | minimum pattern duration | 50 ns |
gate time | 200 ns to 50 s | |
event counts | up to 232 – 1 | |
Trigger generator | output to PXI trigger | XTO input to trigger units |
Synchronization | ||
Trigger units | 2, fully independent hardware trigger logic | |
Applications | ? programmable trigger generator ? generation of realtime stimulation clock ? generation of realtime acquisition clock ? frequency measurement | |
Synchronization inputs | ? 1, local TTL trigger (XTI) ? 8, PXI trigger bus ? 1, pattern comparator | |
Trigger unit characteristics 4) | reference pattern | 10 bit, 3 states: high, low, don’t care |
slope | positive/negative | |
delay | 25 ns to 50 s | |
output signals | ? trigger received signal (25 ns pulse) ? trigger active signal (start of trigger until end of burst) ? sample pulse (25 ns pulse for each sample) | |
Synchronization outputs | ? 1, local TTL trigger (XTO) ? 8, PXI trigger bus | |
Signals | ? output, trigger unit 1 (IT1) ? output, trigger unit 2 (IT2) ? output, pattern comparator ? input signal to trigger unit (XTI) | |
External clock | ||
Input voltage | 5 V TTL | |
Frequency range | 20 MHz to 40 MHz | |
General data | ||
Power consumption | 40 W, mainly powered from 3.3 V/typ. 2.5 A and 5 V/typ. 4.5 A 5) | |
Environmental conditions | ||
Temperature | operating temperature range | +5 °C to +40 °C |
storage temperature range | –10 °C to +60 °C | |
Damp heat | +40 °C, 80 % rel. humidity, steady state, in line with EN 60068-2-30 | |
Mechanical resistance | ||
Vibration | sinusoidal | 5 Hz to 55 Hz, 0.15 mm const. amplitude, 55 Hz to 150 Hz, 0.5 g const., in line with EN 60068-2-6 |
random | 10 Hz to 300 Hz, acceleration 1.2 g (RMS), in line with EN 60068-2-64 | |
Shock | 40 g shock spectrum, in line with MIL-STD-810E, method 516.4 | |
Product conformity | ||
Electromagnetic compatibility | EU: in line with EMC Directive 2004/108/EC | applied harmonized standards: EN 61326-1 (industrial environment), EN 61326-2-1, EN 55011 (class A), EN 61000-3-2, EN 61000-3-3 |
Electrical safety | EU: in line with Low Voltage Directive 2006/95/EC | applied harmonized standard: EN 61010-1 |
Dimensions | W ? H ? D | 20 mm ? 174 mm ? 316 mm (0.8 in ? 6.8 in ? 12.4 in) |
Weight | 0.75 kg (1.65 lb) |